EDF05RROHS
¿¢½º·¹ÀÌ ±Ý¼Ó¼ººÐºÐ¼®±â
Energy Dispersive X-Ray Fluorescent equipment
EDF05RROHS
Measuring chamber:
H440mm x W300mm x D300mm weight 30Kg(net) Inside Sample area : H115mm x W270mm x D230mm
0-50KVp, max.1.mA . Optimized to give a best performance on application HV generator
Air cooled Oil-insulated W-target, thinned Be-windows, X-ray tube
High-performance, High-accuracy, Long-life cycle, radiation safe shielding designed
0-50KV, max.50VA. Software controlled, variable application optimized X-ray power
1mm collimator size, Optimized Collimator setting depend on sample size and analytic Element
5 Filter auto changer for analysis application and focusing interesting Elements
Analysis range: S(Z=16) ~ U(92)
Detection limits : down to 1ppm (Optional down to the 0.1ppm) ~ up to 100 wt%
Super-SDD detector : °ËÃâºÎ¸éÀû 50 mm
thick. Energy Resolution about 149 eV FWHM ( at 5,9 keV) 25 thick Be- entrance window, electrical Peltier
cooling. Digital Pulse Processor. State of the art counting electronics for highest count rate throughput at minimal
dead time and peak shift. Pile- up rejection with automatic dead time correction
Color video system with CCD camera field of view 4x3mm or 2x1.5mm, dual magnification approx 40X or 80X
Electronic safety : The instrument has a CE registration for electrical safety, Radiation safety.
Main supply 110V/230V 60Hz/50Hz
System Analyzer:
High performance-High efficiency precision X-Ray Fluorescence XRF analyzer.
MS-office package for DateMasteR and ReportMasteR option program.
MCA(Multi Channel Analyzer) 2048 channel successive approximation ADC, spectrum board display. Optimized
application for reading and analysis spectrum.
Auto setting and adjustment measurement condition.
Base correction (Base background line correction). Dead time correction. Density correction
KLM marked unknown elements analyze. Elements display function on spectra
Software features : Operating software with WINDOWS 2000/NT/XP using modern PC Technology
Rohs Element analysis software package for Pb, Cd, Br, Cr, Hg Cl
Halogen Elements Analysis application
FP method analysis Fundamental Parameter Method useless standards
Calibration method Create calibration curve for optimized application
Report with DATABASE on EXCEL or WORD Print out or storage of user created report form.
*
¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óÇ°Á¤º¸°í½Ã
Á¦Ç°¸í |
°í¹« ±Ý¼Ó¼ººÐºÐ¼®±â /¿¢½º·¹ÀÌ Áß±Ý¼Ó ÃøÁ¤±â ,EDF05RROHS |
ÆǸŰ¡°Ý |
°¡°Ý¹®ÀÇ |
¿ø»êÁö |
Japan |
¹ÝÇ°±³È¯ |
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.
!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù. |
¹è¼Û¾È³» |
°áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.) |
°áÁ¦¾È³» |
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù. |