Thermo Scientific SPECTRONIC spectrophotometers have served as core analytical instruments in school,
college and university teaching laboratories since 1953. The SPECTRONIC¢â 200 visible spectrophotometer
continues this tradition as the new standard for the 21st century. Robust, innovative features ensure
an excellent teaching instrument that will last. Delivering quick, convenient measurements in the
hands of novice users, the SPECTRONIC 200 spectrophotometer is the perfect fit for the teaching lab.
¡ß Á¦Á¶»ç : Thermo Scientific
¡ß ¿ëµµ : Double beam±¸Á¶ÀÇ Dual Photo diodes¸¦ ÀÌ¿ëÇÑ Á¤¹ÐÈÇкм®
¡ß »ó¼¼¼³¸í
Evolution 200 series´Â double beam typeÀ¸·Î dual silicon photodiodes¸¦ »ç¿ëÇÏ¿© º¸´Ù Á¤È®ÇÑ ºÐ¼®ÀÌ °¡´ÉÇÏ¸ç ³ôÀº ¼öÁØÀÇ resolution°ú accuracy ¹× repeatability·Î ÃÖ»óÀÇ °á°ú¸¦ ¾òÀ» ¼ö ÀÖ´Ù.
ƯÈ÷ Evolution 220 modelÀº Application Focused Beam Geometry ±â¼ú·Î Solid, Materials, fiber optic, ±×¸®°í microcell applications¿¡ ÃÖ»óÀÇ È¿À²À» ÀÚ¶ûÇÑ´Ù.
¶Ç CUE operating software¸¦ ÀÌ¿ëÇÏ¿© °í°´ÀÇ »ç¿ë ¸ñÀû ¹× ¿ä±¸¿¡ ¸Â°Ô ÃøÁ¤ ÀýÂ÷ÀÇ ÀÚµ¿È ¹× °£¼ÒÈ·Î º¸´Ù È¿À²ÀûÀÎ ºÐ¼®¾÷¹«¸¦ µµ¿ÍÁØ´Ù.
Validation ¹× Hands-Free Performance verification °ú 21 CFR Part 11 compliance ¸¦ Àû¿ëÇÏ¿© ¸ðµç ºÐ¾ß¿¡¼ ¾ÈÁ¤ÀûÀ¸·Î »ç¿ë °¡´ÉÇÏ¸ç ½Å·Ú¼ºÀ» °®´Â´Ù.
¡ß »ç¾ç
Optical Design : Double-beam, (Evolution 220 : Application Focused Beam Geometry)
Light Source : Xenon lamp
Detector : Dual Photodiodes
Spectral Bandwidth : 1.0nm
Wavelength Range : 190 to 1100nm
Wavelength Accuracy : ¡¾0.5nm(546.11nm mercury line)
Wavelength Repeatability : ¡Â0.1nm
Photometric Accuracy : ¡¾0.004A at 0.5A, ¡¾0.006A at 1A, ¡¾0.010A at 2A
Baseline Flatness : ¡¾0.0010A(200-800nm)
Á¦Ç° »ç¾ç
ÀÏ»óÀûÀÎ ¿¬±¸ ºÐ¼®, ½Ã¸®Áî Á¦°øÇÕ´Ï´Ù ½ÇÁ¦ Çõ½Å Á¦°øÇÏ´Â Çâ»óµÈ °¡¿ë¼º°ú ¼º´É- ¾Ê°í Ãß°¡ º¹À⼺. °£´ÜÇÑ ¼ÒÇÁÆ®¿þ¾î, Àý´Ü- ¿¡Áö °èÃø ¹× ¾×¼¼¼¸®ÀÇ ´Ù¾çÇÑ ¼±ÅÃÀ», Áø
ȸ¦ 201 220 ½Ã½ºÅÛ ÀÛ¾÷À» ´ç½Å°ú ÇÔ²² ½ÇÇèÀ» ¼öÇàÇϱâ À§ÇØ ¿øÇÏ´Â ¹æ½ÄÀ¸·Î- ´ç½ÅÀÌ ÇÊ¿ä·ÎÇÏ´Â °á°ú¸¦³»ÁØ´Ù .
ÅëÂû·Â ¼ÒÇÁÆ®¿þ¾î ¹× mdash¸¦, ¼¼·ÃµÈ ´Ü¼øÈ
•°³ÀÎÈ ±ÍÇÏÀÇ È¨ ȸéÀ¸·Î ½±°Ô Ž»öÇÏ°í ÆíÀǸ¦
•ÅëÇÕ µµ±¸ ½Ã°£À» Àý¾àÇÏ°í Á¤È®ÇÑ °á°ú¸¦ º¸Àå
•Å¥ ½ºÅ©¸³Æ® »ý¼º ÇÒ ¼ö ÀÖ½À´Ï´Ù »ç¿ëÀÚ Á¤ÀÇ ¿öÅ© Ç÷οì ÀÎÅÍÆäÀ̽º¿Í ´Ü¼øÈ
ÃÖÀûÈ µÈ ¿£Áö´Ï¾î¸µ ÃÖ°íÀÇ ¼º´ÉÀ» Á¦°øÇÕ´Ï´Ù
•´õºí- ºö Çü»ó 1nm ½ºÆåÆ®·³ ´ë¿ªÆø Á¤¹Ð ÃøÁ¤
•ÀÀ¿ë ÇÁ·Î±×·¥ ÁýÁß ºö Çü»ó( afbg) ±â¼úÀ» ÃÖ»óÀÇ ¼º´ÉÀ» °¡´ÉÇÏ°Ô ¿¡¼ ¸¶ÀÌÅ©·Î ¼¿, °íü »ùÇÃÀ», ¹× ±¤¼¶À¯ ÇÁ·Îºê
•Å©¼¼³í Ç÷¡½Ã ·¥ÇÁ ÇÊ¿äÇÏÁö ¾Ê½À´Ï´Ù µû¶æÇÑ- ½Ã°£±îÁö Çã¿ë ÀνºÅÏÆ® ÃøÁ¤
•ÀüÀÚ ½ÇÇà Á¤È®µµ ³ôÀº ¼öÁØÀ» Á¦°øÇÕ´Ï´Ù ºü¸¥- È¥ÇÕ ¼Óµµ·Ð ÃøÁ¤
•Á¤¹Ð ´Ü»öÈ µå¶óÀ̺ê Á¦°øÇÕ´Ï´Ù ºü¸¥ ½ºÄµ µ¥ÀÌÅÍ ¼öÁý ¹× ÆÄÀå Á¤È®µµ
±ÍÇÏÀÇ ¼Õ³¡¿¡¼ °·ÂÇÑ ÆíÀǸ¦
•»ö»ó, ÅÍÄ¡ ½ºÅ©¸° Á¦°øÇÕ´Ï´Ù ¾Ç±â »ç¿ëÇÏ¿© Á¦¾î ³»Àå- ÄÄÇ»ÅÍ
•ÅëÇÕ Å°Æеå ÅëÂû·Â Åë½ÅÀ» ÇÒ ¼ö ÀÖ½À´Ï´Ù ¼ÒÇÁÆ®¿þ¾î
•¼±Åà ·ÎÄà ¶Ç´Â PC ±¸¼º À¯¿¬¼º°ú Æí¸®ÇÔÀ» Á¦°øÇÕ´Ï´Ù
¾×¼¼¼¸® ¸ðµç ¿ä±¸¿¡ ±ÍÇÏÀÇ »ùÇøµ
•´Ù¾çÇÑ ¾×¼¼¼¸® ´Ù¾çÇÑ ¿Âµµ Á¦¾î ¿É¼ÇÀ» ¼±ÅÃ, »ùÇà üÀÎÀú, sippers¿Í °íü »ùÇøµ ÀåÄ¡ ºÐ¼® ¿Ï·áÇÕ´Ï´Ù
•¼±Åà ÆçƼ¿¡ ´ÜÀÏ ¼¿ Ȧ´õ ¶Ç´Â ½º¸¶Æ® 8- ¼¼Æ÷ ÆçƼ¿¡ ½Ã½ºÅÛ ¿Âµµ Á¦¾î ¹× ¸ð´ÏÅ͸µ »ùÇà 0¿¡¼ ¹× ¡É ÀÏ, 100 ¡Æ, C
•½¬¿î ¼ÒÇÁÆ®¿þ¾î ÅëÇÕ ´ç½Å¿¡°Ô ¿Ïº®ÇÏ°Ô Á¦¾î ÇÒ ¼ö ÃøÁ¤ÀÇ
º¸Áõ ½Ã½ºÅÛÀÇ ¼º´É
•¿ °úÇÐ UV °Ë»ç±â ÆÐÅ°Áö ´ëÇÑ Áö¿øÀ» Á¦°øÇÕ´Ï´Ù ½Ã½ºÅÛ ÀÚ°Ý ¹× °ËÁõ È°µ¿
•¹®¼ ¿ëÀÌÇÏ°ÔÇÕ´Ï´Ù Áؼö ½Ã½ºÅÛÀÇ ¿ä±¸ »çÇ׿¡ FDA, GXP, ISO 9001:2000 ¹× ispe 2001 Áöħ ¹× ±ÔÁ¤À»
•¼öÀº ·¥ÇÁ ¾×¼¼¼¸®´Â ¾Ç±â ±³Á¤ ¼öÇà ÇÒ ¼ö
•¿ °úÇÐ ÅëÂû·Â º¸¾È ¼ÒÇÁÆ®¿þ¾î ¿ÏÀüÇÑ Á¦°øÇÏ´Â ÃæÁ·Çϱâ À§ÇØ µµ±¸ 21 CFR ÆÄÆ® 11 ¿ä±¸¿¡
¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óÇ°Á¤º¸°í½Ã
Á¦Ç°¸í |
ºÐ±¤ ±¤µµ°è , UV-Vis ºÐ±¤±¤µµ°è, Evolution 201 ,SPECTRONIC¢â 200 |
ÆǸŰ¡°Ý |
19,600,000¿ø |
ºê·£µå |
Thermo |
Á¦Á¶»ç |
Thermo |