    °¡½ºÀÚµ¿Áõ¹ß³óÃà±â Gas-injected Automated Evaporator
    ½ÇÀç°¡°ÝÀÌ ¾Æ´Õ´Ï´Ù
    ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
    ºê·£µå GYRO
    Á¦Á¶»ç GYRO
    Á¦Ç°ÄÚµå HV-300
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦

     

    Fast and economic concentration through efficient control of gas inlet

    More samples at a time (up to 32 samples)







    Features

    Four Independent Timer Settings for Gas Injection Channels, each with 8 nozzles, allows each channel to be controlled
         separately,allowing different volumes and solvents to be evaporated simultaneously
    Two Step Control of Gas/Air Injection pressure/time, allows both initial and running pressure to be altered on a time base.
        This allows a gradual change of pressure to prevent ¡°bumping¡± of the sample on start up
    Semi-helical Gas/Air flow via specially designed nozzles, generates a large sample surface area, to maximise the rate of evaporation
    Temperature control of the water bath from ambient to 99¡ÆC
    Status monitoring incorporating ¡°traffic light¡± indication for heater, ventilation/extract fan and door closure.
          When all is OK the light is yellow, if there is malfunction or set is incorrect the corresponding light is red
    Blue back-lighting to the sample chamber gives excellent definition for viewing the samples via either front or side windows.
          The light is on/off controlled by a separate switch on the back
    Rear mounted extract/ventilation fan for rapid exhaust of gas/vapours (connection to duct & exhaust via fume hood)
    Tempered Glass panels to chamber front, sides and top lid
    Drain valve + hose for easy replacement of bath water
    Diverse range of sample racks catering for various sample containers



     

     

    Diagram
    Semi-helical Gas/Air flow via specially designed nozzles, generates a large surface area, to maximise the rate of evaporation
    Air or N2 at a set pressure is continuously injected via a nozzle and corresponding valve gas line
    Air or N2 blows down from the nozzle to the bottom of the sample tube, creating ¡°vortex¡±

          thereby increasing the surface area, thus the rate of evaporation
    Evaporated solvents are evacuated by the internal extract fan



    Sample Capacity

    Number of samples

    6~32

    Sample volume (§¢)

    5~300

    Pressure

    Gas

    Compressed air, Nitrogen, etc

    Operating gas pressure (psi)

    15~50

    Pressure control

    Automated 2 step control (initial & operating pressure)

    Time length of initial pressure (min)

    ~99

    Time control (min)

    ~999 (4 independent)

    Water bath temperature (¡É)

    ~99

    Forced evacuation of vapor gas

    Yes (by fan)

    Power

    220 VAC, 350 VA max

    Dimension ( W x D x H, mm)

    590 x 340 x 320

    Weight (Kg)

    26.5

    Cat. No.

    HV300101





    ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
    »óÇ°Á¤º¸°í½Ã
    Á¦Ç°¸í °¡½ºÀÚµ¿Áõ¹ß³óÃà±â Gas-injected Automated Evaporator
    ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
    ºê·£µå GYRO
    Á¦Á¶»ç GYRO
    °ü·Ã»óÇ°
        
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
      »óÇ°¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹ÝÇ°±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    »óÈ£ : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷     ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ32     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 (Á¤º¸È®ÀÎ)
    Åë½ÅÆǸž÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ : 121-86-02196     °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆü­ºñ½ºÁ¦°ø¾÷ü :